22PF-1UF
- Product SKU: 22PF-1UF
- Category: Belimo, HVAC Controls, Sensors & Switches for HVAC
Belimo Ultrasonic Flow Sensor 22PF-1UF: Accurate glycol content and flow rate measurement for closed water systems. Versatile, easy setup with Belimo Assistant App via NFC technology. Choose from multiple communication options for seamless integration.
Size and Flow Rate:
Type | DN | G ["] | FS [l/s] | FS [m³/h] |
kvs theor.[m³/h] |
PN |
22PF-1UC | 15 | 3/4 | 0.5 | 1.8 | 3.9 | 25 |
22PF-1UD | 20 | 1 | 0.83 | 3 | 7.2 | 25 |
22PF-1UE | 25 | 1 1/4 | 1.17 | 4.2 | 13.2 | 25 |
22PF-1UF | 32 | 1 1/2 | 2 | 7.2 | 16 | 25 |
22PF-1UG | 40 | 2 | 3.33 | 12 | 23.6 | 25 |
22PF-1UH | 50 | 2 1/2 | 5 | 18 | 32 | 25 |
Specifications:
Electrical data | Nominal voltage | AC/DC 24 V |
Nominal voltage frequency | 50/60 Hz | |
Nominal voltage range | AC 19.2...28.8 V / DC 21.6...28.8 V | |
Power consumption AC | 2.2 VA | |
Power consumption DC | 1.1 W | |
Connection supply | Cable , 6 x 0.75 mm² | |
Data bus communication | Communication | BACnet MS/TP |
Modbus RTU | ||
MP-Bus | ||
Number of nodes | BACnet / Modbus see interface description | |
MP-Bus max. 8 (16) | ||
Functional data | Application | Water |
Water-glycol mixture | ||
Parametrization | via NFC, Belimo Assistant App | |
Voltage output | 1 x 0...10 V, 0.5...10 V, 2...10 V or user defined | |
Output signal active note | DC 0...10 V (factory setting), selectable via NFC | |
max. load 1 mA | ||
User defined: | ||
- Lower limit: 0...8 V | ||
- Upper limit: 2...10 V | ||
Pipe connection | External thread according to ISO 228-1 | |
Installation position | upright to horizontal | |
Servicing | maintenance-free | |
Measuring data | Measured values | Flow |
Temperature | ||
Measuring fluid | Water and water-glycol mixtures | |
Measuring principle | Ultrasonic volumetric flow measurement | |
Measuring accuracy flow | ±2% (of 20...100% FS) @ 20°C / glycol 0% vol. | |
Measuring accuracy flow note | Additional information on measuring accuracy | |
(with diagram) can be found in the section | ||
"Measuring accuracy". | ||
Min. flow measurement | 0.2% of FS | |
Materials | Fluid wetted parts | Brass nickel-plated, Brass, Stainless steel, |
Aramid fibre, PEEK, EPDM | ||
Flow measuring pipe | Brass body nickel-plated | |
Safety data | Protection class IEC/EN | III, Protective Extra-Low Voltage (PELV) |
Degree of protection IEC/EN | IP54 | |
Degree of protection NEMA/UL | NEMA 2 | |
EMC | CE according to 2014/30/EU | |
Certification IEC/EN | IEC/EN 60730-1:11 and IEC/EN 60730-2-15:10 | |
Quality Standard | ISO 9001 | |
Type of action | Type 1 | |
Rated impulse voltage supply | 0.8 kV | |
Pollution degree | 3 | |
Ambient humidity | Max. 95% RH, non-condensing | |
Ambient temperature | -30...55°C [-22...130°F] | |
Fluid temperature | -20...120°C [-5...250°F] | |
At a fluid temperature of < 2°C [< 36°F], frost | ||
protection must be guaranteed |
Belimo Ultrasonic Flow Sensor 22PF-1UF: Accurate glycol content and flow rate measurement for closed water systems. Versatile, easy setup with Belimo Assistant App via NFC technology. Choose from multiple communication options for seamless integration.
Size and Flow Rate:
Type | DN | G ["] | FS [l/s] | FS [m³/h] |
kvs theor.[m³/h] |
PN |
22PF-1UC | 15 | 3/4 | 0.5 | 1.8 | 3.9 | 25 |
22PF-1UD | 20 | 1 | 0.83 | 3 | 7.2 | 25 |
22PF-1UE | 25 | 1 1/4 | 1.17 | 4.2 | 13.2 | 25 |
22PF-1UF | 32 | 1 1/2 | 2 | 7.2 | 16 | 25 |
22PF-1UG | 40 | 2 | 3.33 | 12 | 23.6 | 25 |
22PF-1UH | 50 | 2 1/2 | 5 | 18 | 32 | 25 |
Specifications:
Electrical data | Nominal voltage | AC/DC 24 V |
Nominal voltage frequency | 50/60 Hz | |
Nominal voltage range | AC 19.2...28.8 V / DC 21.6...28.8 V | |
Power consumption AC | 2.2 VA | |
Power consumption DC | 1.1 W | |
Connection supply | Cable , 6 x 0.75 mm² | |
Data bus communication | Communication | BACnet MS/TP |
Modbus RTU | ||
MP-Bus | ||
Number of nodes | BACnet / Modbus see interface description | |
MP-Bus max. 8 (16) | ||
Functional data | Application | Water |
Water-glycol mixture | ||
Parametrization | via NFC, Belimo Assistant App | |
Voltage output | 1 x 0...10 V, 0.5...10 V, 2...10 V or user defined | |
Output signal active note | DC 0...10 V (factory setting), selectable via NFC | |
max. load 1 mA | ||
User defined: | ||
- Lower limit: 0...8 V | ||
- Upper limit: 2...10 V | ||
Pipe connection | External thread according to ISO 228-1 | |
Installation position | upright to horizontal | |
Servicing | maintenance-free | |
Measuring data | Measured values | Flow |
Temperature | ||
Measuring fluid | Water and water-glycol mixtures | |
Measuring principle | Ultrasonic volumetric flow measurement | |
Measuring accuracy flow | ±2% (of 20...100% FS) @ 20°C / glycol 0% vol. | |
Measuring accuracy flow note | Additional information on measuring accuracy | |
(with diagram) can be found in the section | ||
"Measuring accuracy". | ||
Min. flow measurement | 0.2% of FS | |
Materials | Fluid wetted parts | Brass nickel-plated, Brass, Stainless steel, |
Aramid fibre, PEEK, EPDM | ||
Flow measuring pipe | Brass body nickel-plated | |
Safety data | Protection class IEC/EN | III, Protective Extra-Low Voltage (PELV) |
Degree of protection IEC/EN | IP54 | |
Degree of protection NEMA/UL | NEMA 2 | |
EMC | CE according to 2014/30/EU | |
Certification IEC/EN | IEC/EN 60730-1:11 and IEC/EN 60730-2-15:10 | |
Quality Standard | ISO 9001 | |
Type of action | Type 1 | |
Rated impulse voltage supply | 0.8 kV | |
Pollution degree | 3 | |
Ambient humidity | Max. 95% RH, non-condensing | |
Ambient temperature | -30...55°C [-22...130°F] | |
Fluid temperature | -20...120°C [-5...250°F] | |
At a fluid temperature of < 2°C [< 36°F], frost | ||
protection must be guaranteed |
Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.
Cancellations :
– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.
Return Policy :
If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.
Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:
- Any product that exhibits physical damage to the box or to the product;
- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;
- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;
- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;
Replacements :
– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.
– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.
- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same
- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.
Refund :
Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).