Image

DEFINITION OF TERMS
• Automatic Reset: A type of thermostat that will automatically reset at a specific temperature (i.e. a thermostat operates at
65,5 oC [150 oF] and resets at 48,89 oC [120 oF]).
• Bimetal: Two dissimilar metals bonded together to form the material for manufacturing thermally-sensitive discs which actuate
the thermostat.
• Close on Rise (COR): Refers to operation of the contacts. When the temperature rises to its set point, the contacts close or
make contact and complete the circuit.
• Contact Resistance: The value of resistance measured between the terminals.
• Dielectric Strength: The value of insulation between two electrically conducting parts. It may be tested by the application of a
predetermined overvoltage for a specified time.
• Differential: The temperature difference between the operate and reset set points, also known as operate and reset.
- Nominal: The temperature difference between nominal set points regardless of tolerance.
- Maximum: Maximum number of degrees between actual opening and closing set points.
- Minimum: Minimum number of degrees between actual opening and closing set points.
• Exposure Temperature: Thermal environment of a device during application operation.
• FLA (Full Load Amps): Current taken from the line by the motor when the motor is yielding the rated hp at the rated voltage
and frequency.
• Life Cycles: The endurance rating of the thermostat expressed in number of operations with stated electrical load applied.
Temperature limit application = open on rise.
• LRA (Locked Rotor Amps): The amount of current the motor can be expected to draw under starting conditions when full
voltage is applied, also known as starting inrush current.
• Manual Reset: A bimetal thermostat with a reset button that must be pressed to reset the contacts.
• Open on Rise (OOR): Refers to the operation of contacts. When the temperature rises to its set point the contacts open,
terminating the circuit.
• Overmold: Encapsulation with an insulating material.
• Phenolic: Thermoset plastic used for the insulating body of the thermostat.
• Set Point: The nominal temperature at which the thermostat operates.
• SPST (Single Pole/Single Throw): A switch with one current path which can be either open or closed.
• Tolerance: The allowable range above and below the set point temperature.
• Operate: Change of state when the thermostat reaches its set point.
• Reset: Change of state when the thermostat returns to its original condition prior to operation.
NOTES
• Standard Temperature Characteristics Tables:
- Temperatures: Please consult applications engineering for temperature ranges, tolerances and differentials not noted.
The operating temperature ranges include tolerances.
- Tolerances: The ± tolerances given have been established after review of many thermostat applications. Attempts should
be made to establish the widest acceptable tolerance possible.
• UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into
equipment.
• Fan control applications: Require thermostat set points to be derated by 20 °C from the equivalent temperature limit
application. They also close on rise.
• Dimensions: Are for reference only and are given in mm [in].

DEFINITION OF TERMS
• Automatic Reset: A type of thermostat that will automatically reset at a specific temperature (i.e. a thermostat operates at
65,5 oC [150 oF] and resets at 48,89 oC [120 oF]).
• Bimetal: Two dissimilar metals bonded together to form the material for manufacturing thermally-sensitive discs which actuate
the thermostat.
• Close on Rise (COR): Refers to operation of the contacts. When the temperature rises to its set point, the contacts close or
make contact and complete the circuit.
• Contact Resistance: The value of resistance measured between the terminals.
• Dielectric Strength: The value of insulation between two electrically conducting parts. It may be tested by the application of a
predetermined overvoltage for a specified time.
• Differential: The temperature difference between the operate and reset set points, also known as operate and reset.
- Nominal: The temperature difference between nominal set points regardless of tolerance.
- Maximum: Maximum number of degrees between actual opening and closing set points.
- Minimum: Minimum number of degrees between actual opening and closing set points.
• Exposure Temperature: Thermal environment of a device during application operation.
• FLA (Full Load Amps): Current taken from the line by the motor when the motor is yielding the rated hp at the rated voltage
and frequency.
• Life Cycles: The endurance rating of the thermostat expressed in number of operations with stated electrical load applied.
Temperature limit application = open on rise.
• LRA (Locked Rotor Amps): The amount of current the motor can be expected to draw under starting conditions when full
voltage is applied, also known as starting inrush current.
• Manual Reset: A bimetal thermostat with a reset button that must be pressed to reset the contacts.
• Open on Rise (OOR): Refers to the operation of contacts. When the temperature rises to its set point the contacts open,
terminating the circuit.
• Overmold: Encapsulation with an insulating material.
• Phenolic: Thermoset plastic used for the insulating body of the thermostat.
• Set Point: The nominal temperature at which the thermostat operates.
• SPST (Single Pole/Single Throw): A switch with one current path which can be either open or closed.
• Tolerance: The allowable range above and below the set point temperature.
• Operate: Change of state when the thermostat reaches its set point.
• Reset: Change of state when the thermostat returns to its original condition prior to operation.
NOTES
• Standard Temperature Characteristics Tables:
- Temperatures: Please consult applications engineering for temperature ranges, tolerances and differentials not noted.
The operating temperature ranges include tolerances.
- Tolerances: The ± tolerances given have been established after review of many thermostat applications. Attempts should
be made to establish the widest acceptable tolerance possible.
• UL and CSA Approvals: 12,7 mm [0.5 in] thermostats are available with multiple agency approval for incorporation into
equipment.
• Fan control applications: Require thermostat set points to be derated by 20 °C from the equivalent temperature limit
application. They also close on rise.
• Dimensions: Are for reference only and are given in mm [in].

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).