Belimo EXT-KA-SQ100 Indoor Air Quality Sensor elevates IAQ with real-time monitoring of Temperature, Humidity, CO₂, PM2.5, PM10, and TVOC. Boost LEED, WELL, and RESET certifications. Enjoy easy installation, multiple power options, and seamless connectivity. Breathe easy, live better!
It works on single phase power supply 100-240VAC.
Specifications:
Data bus communication | Communication | Modbus RTU Local and cloud MQTT Open API Cloud |
Functional data | Coverage area | Area: 325 m² [3500 ft²] |
Measuring data | Measured values | CO₂ TVOC PM2.5, PM10 Relative humidity Temperature |
Specification Particulate Matter | Mesurement range | Mass concentration range: 0...1000μg/m³ PM2.5 mass concentration size range: 0.3...2.5 μg/m³ |
Accuracy | ±3 μg/m³ (0to30μg/m³); ±10% m.v. (30...1000μg/m³) | |
Typical response time | ≤10 s | |
Sensor output resolution | 1μg/m³ | |
Sensor technology | Laser particle sensor (light scattering) | |
Specification TVOC | Mesurement range | 0...60000 ppb |
Accuracy | ±15% ±8 ppb | |
Typical startup time | 0.4 ms | |
Sensor output resolution | 1 ppb | |
Sensor technology | Multi-pixel metal oxide sensor (MOx) | |
Specification CO₂ | Mesurement range | 400...2000 ppm Up to 10000 ppm extended range |
Accuracy | ±3% m.v. ±50 ppm | |
Typical response time | 120 s by 90% | |
Sensor output resolution | 1 ppm | |
Sensor technology | Non-dispersive infrared (NDIR) | |
Specification Temperature | Mesurement range | -20...100°C |
Accuracy | ±1°C | |
Typical response time | >2 s | |
Sensor output resolution | 0.01°C | |
Long Term Drift | <0.03°C [0.054°F]/yr (under normal RH/T operating range) | |
Specification Humidity | Mesurement range | 0...99% RH |
Accuracy | ±5% RH | |
Typical response time | >8 s (depends on the surrounding surface and the airflow in the final application environment) | |
Sensor output resolution | 0.01% RH | |
Long Term Drift | <0.25% RH/yr | |
Safety data | EU Conformity | CE Marking |
Ambient humidity | Max. 95% RH, non-condensing | |
Ambient temperature | 0...50°C [32...122°F] |
Belimo EXT-KA-SQ100 Indoor Air Quality Sensor elevates IAQ with real-time monitoring of Temperature, Humidity, CO₂, PM2.5, PM10, and TVOC. Boost LEED, WELL, and RESET certifications. Enjoy easy installation, multiple power options, and seamless connectivity. Breathe easy, live better!
It works on single phase power supply 100-240VAC.
Specifications:
Data bus communication | Communication | Modbus RTU Local and cloud MQTT Open API Cloud |
Functional data | Coverage area | Area: 325 m² [3500 ft²] |
Measuring data | Measured values | CO₂ TVOC PM2.5, PM10 Relative humidity Temperature |
Specification Particulate Matter | Mesurement range | Mass concentration range: 0...1000μg/m³ PM2.5 mass concentration size range: 0.3...2.5 μg/m³ |
Accuracy | ±3 μg/m³ (0to30μg/m³); ±10% m.v. (30...1000μg/m³) | |
Typical response time | ≤10 s | |
Sensor output resolution | 1μg/m³ | |
Sensor technology | Laser particle sensor (light scattering) | |
Specification TVOC | Mesurement range | 0...60000 ppb |
Accuracy | ±15% ±8 ppb | |
Typical startup time | 0.4 ms | |
Sensor output resolution | 1 ppb | |
Sensor technology | Multi-pixel metal oxide sensor (MOx) | |
Specification CO₂ | Mesurement range | 400...2000 ppm Up to 10000 ppm extended range |
Accuracy | ±3% m.v. ±50 ppm | |
Typical response time | 120 s by 90% | |
Sensor output resolution | 1 ppm | |
Sensor technology | Non-dispersive infrared (NDIR) | |
Specification Temperature | Mesurement range | -20...100°C |
Accuracy | ±1°C | |
Typical response time | >2 s | |
Sensor output resolution | 0.01°C | |
Long Term Drift | <0.03°C [0.054°F]/yr (under normal RH/T operating range) | |
Specification Humidity | Mesurement range | 0...99% RH |
Accuracy | ±5% RH | |
Typical response time | >8 s (depends on the surrounding surface and the airflow in the final application environment) | |
Sensor output resolution | 0.01% RH | |
Long Term Drift | <0.25% RH/yr | |
Safety data | EU Conformity | CE Marking |
Ambient humidity | Max. 95% RH, non-condensing | |
Ambient temperature | 0...50°C [32...122°F] |
Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.
Cancellations :
– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.
Return Policy :
If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.
Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:
- Any product that exhibits physical damage to the box or to the product;
- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;
- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;
- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;
Replacements :
– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.
– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.
- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same
- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.
Refund :
Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).