Image

Danfoss TCBE2 068U4250 Thermostatic Expansion Valve features a fixed orifice, providing precise control over refrigerant flow. Constructed from stainless steel, it is well-suited for refrigeration systems in the food industry and aggressive environments. Specifically designed for swift soldering into hermetic refrigeration systems, the TCBE ensures efficient installation and reliable, corrosion-resistant performance.

Specifications:

Charges available for following refrigerants R290, R134a, R513A, R404A, R407A, R407C, R407F, R448A, R449A, R507, R410A, R452A, R600a, R454C, R455A, R1234yf, R1234ze(E), R454A TU and TC 
Ignition assessment Positive. Zone 2 (Category 3, IIA) TUA/TUAE and TCAE only approved for A1 refrig- erants
Complies with PED Yes, fluid group 2, Article 4 paragraph 3, DN < 25 (inner bore)
Standard charge ranges with MOP -40 – +10 °C / -40 − +50 °F MOP +15 °C / + 60 °F
-40 – -5 °C / -40 − +25 °F MOP 0 °C / +32 °F
-60 – -25 °C / -75 − -15 °F MOP -20 °C / -4 °F (not for R134a and R513A)
Max. working pressure PS/MWP TU (non R410A): 34 bar(g) / 500 psi(g) TU (R410A): 45.5 bar(g) / 660 psi(g) TC (all): 45.5 bar(g) / 660 psi(g)
Connection type Solder, ODF
Connection sizes, Angleway Inlet: 1⁄4 in, 3/8 in, 6 mm, 10 mm Outlet: 3/8 in, 1⁄2 in, 5/8 in, 10 mm, 12 mm, 16 mm
Connection sizes, Straightway Inlet: 1⁄4 in, 3/8 in, 1⁄2 in, 6 mm, 10 mm, 12 mm Outlet: 3/8 in, 1⁄2 in, 5/8 in, 10 mm, 12 mm, 16 mm
Connection sizes, [External equalization] 1⁄4 in, 6 mm
Orifices, TUB(E), TUC(E) X, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Orifices TUA(E) 1, 2, 3, 4, 5, 6, 7, 8, 9
Orifices TCAE, TCBE, TCCE 1, 2, 3
Bleed 15% (of nominal capacity) available. For 30%, contact Danfoss.
Biflow operation With flow in the opposite direction, the rated capacity is reduced by up to 15%.
Biflow not recommended in TU with orifice 9 TC with orifice 3
All valves with MOP charges
Biflow not possible in All valves with internal equalization
Environmental transport/storage temperature and humidity Max. +65 °C / +150 °F, Humidity: <100% RH
Max. body temperature (mounting/operation) +120°C / +250°F (short lived peak: +150°C / +300°F)
Min. body temperature See Evaporating temperature range low end.
Max. bulb temperature (operation) Standard valves: +100°C / +212°F
Valves with MOP charges: +150°C / +300°F
Static superheat (SS) Standard 4K / 7.2°F
Customer-specific settings and non-adjustable valves are available. Please contact Danfoss.
Material of product Body: Stainless steel Capillary tube: Stainless steel
Connector: Bimetal (stainless steel and copper)
Standard capillary tube lengths TU: 0.8 m / 31.5 in
TC: 0.9 m / 35 in
Special capillary tube lengths available 0.3 m / 11.8 in, 0.45 m / 18.0 in and 1.5 m / 59 in
Inlet strainer TU orifice X - 4 = 100 mesh / All other TU and TC = 50 mesh / TU and TC angle = 80 mesh
Serviceable No
Corrosion Passed salt spray test (EN ISO 9227 NSS) and ASTM prohesion (ASTM G85) test. Both 2000 hours

 

Ordering Code:

Refrigerant Type Orifice No. Pressure eq. Connection (in x out)
inch Code No. mm Code No.
R407C TCBE 1 External 1/2x5/8 068U4257 12x16 068U4249
2 068U4258 068U4250
3 068U4251 068U4259
R410A TCBE 1 External 1/2x5/8 068U4265 12x16 068U4273
2 068U4266 068U4274
3 068U4267 068U4275
R134a / R513A TCBE 1 External 1/2x5/8 068U4217 12x16 068U4225
2 068U4218 068U4226
3 068U4219 068U4227
R404A / R507A TCBE 1 External 1/2x5/8 - 12x16 068U4241
2 068U4234 068U4242
3 068U4235 068U4243
R290 TCBE 1 External 3/8x5/8 068U4383 10x16 068U4386
2 1/2x5/8 068U4384 12x16 068U4387
3 068U4385 068U4388
Range N MOP 95 psig / +15 °C
R407C TCBE 1 External 1/2x5/8 068U4253 12x16 068U4261
2 068U4254 068U4262
3 - 068U4263
Range N MOP 165 psig / +15 °C
R410A TCBE 1 External 1/2x5/8 - 12x16 -
2 068U4270 -
3 - 068U4279
Range N MOP 55 psig / +15 °C
R134a/R513A TCBE 1 External - - 10x16 068U4228
2 - 12x16 068U4230
3 - 068U4231
Range N MOP 120 psig / +15 °C
R404A / R507A TCBE 1 External - - 10x16 068U4244
2 - 12x16 068U4246
3 - 068U4247

Danfoss TCBE2 068U4250 Thermostatic Expansion Valve features a fixed orifice, providing precise control over refrigerant flow. Constructed from stainless steel, it is well-suited for refrigeration systems in the food industry and aggressive environments. Specifically designed for swift soldering into hermetic refrigeration systems, the TCBE ensures efficient installation and reliable, corrosion-resistant performance.

Specifications:

Charges available for following refrigerants R290, R134a, R513A, R404A, R407A, R407C, R407F, R448A, R449A, R507, R410A, R452A, R600a, R454C, R455A, R1234yf, R1234ze(E), R454A TU and TC 
Ignition assessment Positive. Zone 2 (Category 3, IIA) TUA/TUAE and TCAE only approved for A1 refrig- erants
Complies with PED Yes, fluid group 2, Article 4 paragraph 3, DN < 25 (inner bore)
Standard charge ranges with MOP -40 – +10 °C / -40 − +50 °F MOP +15 °C / + 60 °F
-40 – -5 °C / -40 − +25 °F MOP 0 °C / +32 °F
-60 – -25 °C / -75 − -15 °F MOP -20 °C / -4 °F (not for R134a and R513A)
Max. working pressure PS/MWP TU (non R410A): 34 bar(g) / 500 psi(g) TU (R410A): 45.5 bar(g) / 660 psi(g) TC (all): 45.5 bar(g) / 660 psi(g)
Connection type Solder, ODF
Connection sizes, Angleway Inlet: 1⁄4 in, 3/8 in, 6 mm, 10 mm Outlet: 3/8 in, 1⁄2 in, 5/8 in, 10 mm, 12 mm, 16 mm
Connection sizes, Straightway Inlet: 1⁄4 in, 3/8 in, 1⁄2 in, 6 mm, 10 mm, 12 mm Outlet: 3/8 in, 1⁄2 in, 5/8 in, 10 mm, 12 mm, 16 mm
Connection sizes, [External equalization] 1⁄4 in, 6 mm
Orifices, TUB(E), TUC(E) X, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Orifices TUA(E) 1, 2, 3, 4, 5, 6, 7, 8, 9
Orifices TCAE, TCBE, TCCE 1, 2, 3
Bleed 15% (of nominal capacity) available. For 30%, contact Danfoss.
Biflow operation With flow in the opposite direction, the rated capacity is reduced by up to 15%.
Biflow not recommended in TU with orifice 9 TC with orifice 3
All valves with MOP charges
Biflow not possible in All valves with internal equalization
Environmental transport/storage temperature and humidity Max. +65 °C / +150 °F, Humidity: <100% RH
Max. body temperature (mounting/operation) +120°C / +250°F (short lived peak: +150°C / +300°F)
Min. body temperature See Evaporating temperature range low end.
Max. bulb temperature (operation) Standard valves: +100°C / +212°F
Valves with MOP charges: +150°C / +300°F
Static superheat (SS) Standard 4K / 7.2°F
Customer-specific settings and non-adjustable valves are available. Please contact Danfoss.
Material of product Body: Stainless steel Capillary tube: Stainless steel
Connector: Bimetal (stainless steel and copper)
Standard capillary tube lengths TU: 0.8 m / 31.5 in
TC: 0.9 m / 35 in
Special capillary tube lengths available 0.3 m / 11.8 in, 0.45 m / 18.0 in and 1.5 m / 59 in
Inlet strainer TU orifice X - 4 = 100 mesh / All other TU and TC = 50 mesh / TU and TC angle = 80 mesh
Serviceable No
Corrosion Passed salt spray test (EN ISO 9227 NSS) and ASTM prohesion (ASTM G85) test. Both 2000 hours

 

Ordering Code:

Refrigerant Type Orifice No. Pressure eq. Connection (in x out)
inch Code No. mm Code No.
R407C TCBE 1 External 1/2x5/8 068U4257 12x16 068U4249
2 068U4258 068U4250
3 068U4251 068U4259
R410A TCBE 1 External 1/2x5/8 068U4265 12x16 068U4273
2 068U4266 068U4274
3 068U4267 068U4275
R134a / R513A TCBE 1 External 1/2x5/8 068U4217 12x16 068U4225
2 068U4218 068U4226
3 068U4219 068U4227
R404A / R507A TCBE 1 External 1/2x5/8 - 12x16 068U4241
2 068U4234 068U4242
3 068U4235 068U4243
R290 TCBE 1 External 3/8x5/8 068U4383 10x16 068U4386
2 1/2x5/8 068U4384 12x16 068U4387
3 068U4385 068U4388
Range N MOP 95 psig / +15 °C
R407C TCBE 1 External 1/2x5/8 068U4253 12x16 068U4261
2 068U4254 068U4262
3 - 068U4263
Range N MOP 165 psig / +15 °C
R410A TCBE 1 External 1/2x5/8 - 12x16 -
2 068U4270 -
3 - 068U4279
Range N MOP 55 psig / +15 °C
R134a/R513A TCBE 1 External - - 10x16 068U4228
2 - 12x16 068U4230
3 - 068U4231
Range N MOP 120 psig / +15 °C
R404A / R507A TCBE 1 External - - 10x16 068U4244
2 - 12x16 068U4246
3 - 068U4247

View Product Catalog

Futuristic believes & will help its customers as far as possible, and has therefore a liberal cancellation policy.


Cancellations :

– Please send an email at sales@futuristicclimatecontrols.in
- Cancellation will be accepted only if the product does not meet the specifications mentioned on our portal.




Return Policy :

If you think, you have received the product in a bad condition or if the packaging is tampered with or damaged before delivery, please refuse to accept the package and return the package to the delivery person. Also, please call our customer care at +91 9723810294 or email us at sales@futuristicclimatecontrols.in mentioning your Order ID. We will personally ensure that a brand new replacement is issued to you with no additional cost. Please make sure that the original product tag and packing is intact when you send us the product back.

Apart from the condition reserved herein above, the following products shall not be eligible for return or replacement, viz:

- Any product that exhibits physical damage to the box or to the product;

- Any product that is returned without all original packaging and accessories, including the retail box, manuals, cables, and all other items originally included with the product at the time of delivery;

- Any product without a valid, readable, untampered serial number, including but not limited to products with missing, damaged, altered, or otherwise unreadable serial number;

- The refund does not include any service or manpower involved while installation, erection, commissioning, training or any such similar activity;




Replacements :

– If you have received the product, it will be eligible for repair/replacement, only in cases where there are defects found with the product. Replacement will be possible only if you ship the product to our office address, all courier charges borne by you. In case of out of country customers, there will be an additional courier charge for the return of the item to the customer country/city.


– All deliveries are F.O.R. Ahmedabad Airport, India. However, all customs & import duties are to be borne by the customer at the country of import. In case of return, the customs & import duties of our country ( India ) , if charged by the authorities, will be deducted from the refund amount. In case of repair, the import/custom duties as levied by Indian Authorities will be to Customer Account.


- In case of complaints regarding products that come with a warranty from manufacturers, please refer the issue to the concerned manufacturer. Let us know & we’ll help you regarding the same


- Replacement will not be valid if the Instrument is tampered or used without following the instruction procedures as mentioned in User manual.



Refund :

Refunds will be made in the same form or by most convenient form ,that the payment is received, within 10 – 15 working days from the date of cancellation of order. However a levy of 3% will be charged towards payment processing charges (Payment Gateway Charges).